CAT6 S/FTP Cable

Rated 0 out of 5
(0 customer reviews)

The DCONNECT CAT6 S/FTP Cable is a high-performance shielded Ethernet cable designed for Gigabit networking, data centers, enterprise infrastructures, CCTV systems, and industrial applications. Constructed with 23 AWG solid bare copper conductors, individually foil-shielded pairs, and an overall braided shield, it delivers superior protection against EMI, crosstalk, and signal interference while ensuring reliable high-speed data transmission.

Datacenter

Server Infrastructure

Telecom

Network Deployment

Enterprise IT

Business Systems

Security Systems

Surveillance Networks

Global Brand

50+ Countries

Worldwide Shipping

Fast Global Delivery

Bulk Supply

Wholesale Solutions

Own Manufacturing

Quality Assured

24/7 Support

Always Available

Overview

Key Features

Applications

Technical Specifications

Downloads

FAQs

Shipping & Warranty

Reviews

Product Overview

The DCONNECT CAT6 S/FTP Cable is engineered to deliver exceptional network performance in environments where signal integrity, electromagnetic protection, and high-speed data transmission are critical. Manufactured using premium 23 AWG solid bare copper conductors, this Category 6 cable features individually foil-shielded twisted pairs combined with an overall braided shield to provide maximum protection against electromagnetic interference (EMI), radio frequency interference (RFI), and alien crosstalk. Designed to support frequencies up to 250 MHz and Gigabit Ethernet applications, the cable ensures stable and reliable connectivity across enterprise networks, data centers, industrial facilities, surveillance systems, and structured cabling infrastructures. The Low Smoke Zero Halogen (LSZH) outer jacket enhances safety by reducing toxic smoke emissions during fire incidents, making it suitable for public buildings, hospitals, educational institutions, and enclosed environments. Its robust construction, excellent electrical characteristics, and compliance with international cabling standards make the DCONNECT CAT6 S/FTP Cable a dependable solution for modern high-performance networking applications.

Key Feautures

The DCONNECT CAT6 S/FTP Cable combines high-performance networking capabilities with advanced shielding technology to deliver reliable and interference-free data transmission. Built with premium 23 AWG solid bare copper conductors, the cable ensures superior conductivity and consistent network performance. Each twisted pair is individually protected with foil shielding while an additional overall braided shield provides enhanced protection against EMI, RFI, and external electrical noise. Supporting frequencies up to 250 MHz and Gigabit Ethernet applications, the cable is ideal for high-speed data communication systems. Its LSZH jacket improves fire safety by minimizing smoke and toxic gas emissions, making it suitable for indoor installations in commercial buildings, hospitals, educational institutions, and data centers. The cable is fully compatible with IEEE 802.3 networking standards and supports PoE and PoE+ applications. Its durable construction, low signal loss, and excellent crosstalk suppression make it an ideal choice for enterprise networking, CCTV systems, industrial automation, and structured cabling projects.

Product Description

The DCONNECT CAT6 S/FTP Cable is a premium-grade structured cabling solution designed for organizations that require dependable, high-speed network connectivity in challenging environments. Featuring 23 AWG solid bare copper conductors, the cable delivers outstanding electrical performance and supports Gigabit Ethernet applications with stable and efficient data transmission.Unlike standard network cables, this Category 6 S/FTP cable incorporates individual foil shielding around each twisted pair along with an overall braided shield. This advanced shielding structure significantly reduces electromagnetic interference, radio frequency interference, and alien crosstalk, ensuring optimal signal quality even in environments with high electrical noise.The cable is designed to operate at frequencies up to 250 MHz and complies with major international networking and cabling standards, including ANSI/TIA, ISO/IEC, IEEE, and IEC specifications. Support for PoE and PoE+ technologies allows simultaneous power and data transmission for IP cameras, wireless access points, VoIP phones, and other network devices.For enhanced safety, the cable is protected by a Low Smoke Zero Halogen (LSZH) jacket that limits smoke generation and toxic gas emissions during fire incidents. This makes it particularly suitable for enclosed public spaces, commercial buildings, educational institutions, healthcare facilities, and mission-critical infrastructure. Combining superior shielding, reliable performance, and international compliance, the DCONNECT CAT6 S/FTP Cable is an ideal solution for modern networking environments requiring secure and high-performance connectivity.

Applications

Data Center

Server Rooms

Telecom Facilities

Network Infrastructure

Security & Surveillance Systems

Government

Banking

Healthcare

Education

Technical Specifications

Product Type

CAT6 S/FTP Cable

Part Number

CC-C6-S/FTP-LZ-305-VL

Cable Category

Category 6

Cable Construction

S/FTP (Shielded Foiled Twisted Pair)

Conductor Material

Solid Bare Copper

Conductor Size

23 AWG

Insulation Material

Foamed Polyolefin / HDPE

Shielding Type

Individual Pair Foil + Overall Braid Shield

Jacket Material

LSZH

Jacket Type

Low Smoke Zero Halogen

Outer Jacket Color

Grey

Outer Diameter

7.2 ± 0.3 mm

Packaging

305m Pull Box / Wooden Drum

Operating Frequency

Up to 250 MHz

Ethernet Support

10/100/1000BASE-T

PoE+ Support

IEEE 802.3at PoE+

Voltage Rating

Max. 72 VDC

Impedance

100 ± 15 Ω

Delay Skew

≤ 45 ns / 100m

DC Resistance @20°C

≤ 9.38 Ω / 100m

Maximum Pulling Force

11.5 kg

Cable Weight

Approx. 12–13 kg / 305m

Operating Temperature

-20°C to +70°C

Flame Test

IEC 60332-1 / IEC 60332-3-22

Smoke Density Test

IEC 61034-2

Downloads

Product Catalogue (PDF)

Product Datasheet (PDF)

Certifications PDF)

Frequently Asked Questions

CAT6 S/FTP Cable is used for Gigabit Ethernet networks, enterprise cabling systems, data centers, CCTV networks, industrial automation, and high-performance structured cabling installations.
S/FTP stands for Shielded Foiled Twisted Pair, where each pair is individually foil shielded and the entire cable is protected by an overall braided shield for maximum interference protection.
Yes. The cable fully supports 10BASE-T, 100BASE-TX, and 1000BASE-T Gigabit Ethernet applications.
Yes. The cable supports IEEE 802.3af PoE and IEEE 802.3at PoE+ technologies.
The LSZH jacket minimizes smoke production and toxic gas emissions during fire incidents, improving safety in enclosed environments.
It is ideal for data centers, enterprise networks, smart buildings, CCTV systems, telecom infrastructures, industrial facilities, and structured cabling projects.

Average Rating

4.5

20 Reviews

All Ratings

20

5

56%

4

40%

3

40%

2

30%

1

0%

Write your Review

Share your feedback and help create a better shopping experience for everyone.

All Reviews (20)

Christopher Lee

June 25, 2026

Excellent shielding quality and easy rack installation. Highly recommended for enterprise networks.

Emily Watson

May 13, 2026

Strong build quality and perfect compatibility with our CAT6 keystone jacks.

Christiana

April 20, 2026

We installed the 2U High Density Fiber Patch Panel in our enterprise data center, and it exceeded our expectations. The build quality is excellent, cable management is neat, and installation was straightforward. The panel provides ample space for high-density fiber connections while maintaining easy access for maintenance. Highly recommended for professional networking and data center deployments.

Get More Information

Contact us for details and support.

Supplier Information

Dconnect

Verified Supplier

Dubai, UAE

Dconnect.ae

+971 555721321

FOLLOW